FIRST SUPPLY:
Design Modification:
Cup depth changed from 1.67 to 1.40 mm BiconcaveD2 with IB90 coating.
Punches were run on 16 RPM, but the issue was not resolved, and thickness also reduced.
SHAPE & SIZE:
20.00 x 9.00 mm/CAPSULE BICONCAVE
ISSUE REPORTED:
Heavy Sticking & Low RPM of Machine.
ROOT CAUSE:
Since the product is a combination of Ibuprofen & Paracetamol (Ibuprofen is of highly sticky nature)
Design Modification:
Cup depth changed from 1.67 to 1.40 mm BiconcaveD2 with IB90 coating.
Punches were run on 16 RPM, but the issue was not resolved, and thickness also reduced.
Design Modification:
Cup depth changed from 1.40 to 1.67 mm BiconcaveKTT CHROMO (Sleipner) For Punches & M35 Grade Steel for Dies with CRCN coating.
With remedies provide in 2nd supply, the machine was run on 24 RPM, the issue got resolved.
To access this article, please fill out the form below.